9,484 conditions across 37 councils · 295 audit errors found across 33 councils · Newcastle, Central Coast, Wollongong added · CB & Lake Mac document checkers live · 37-council directory with LEP links · LEP clause reference + key timeframes ·

Canterbury-Bankstown Parking Conditions

21 parking conditions imposed by Canterbury-Bankstown across 6 development applications in our dataset. Parking conditions specify the number, layout and management of car, motorcycle, bicycle and accessible parking spaces, loading bays, and how parking is allocated and signposted.

Condition 3 DA-1524/2023

3. Add additional Condition 63A under “Building Work Before Issue of a Construction Certificate” Section to read as follows: Electrical Vehicle charging equipment Provision for EV charging in accordance with the below requirements: a. All residential car parking spaces must be ‘EV-Ready’. An ‘EV-Ready’ car space requires the provision of a backbone cable tray and a dedicated spare 15A circuit within an EV Distribution Board enabling future installation of a smart EV charger and cabling to the EV Distribution Board. b. Provide EV Distribution Boards of sufficient size to allow connection of all ‘EV-Ready’ car spaces. c. Locate EV Distribution board(s) so that no future ‘EV-Ready’ car space…

DA-2/2025 det. 08/09/2025

The route for transportation to and from the development site of bulk and excavation materials shall generally be by the shortest possible route to the nearest "regional road", with every effort to avoid school zones on public roads. The consent holder shall nominate the route for approval by Council before commencement of any work on the site. An "Agreement" to Council's satisfaction, signed by consent holder specifying the approved route and acknowledging responsibility to pay Council for damages to public property adjacent to the site shall be lodged with Council before release of any construction certificate. All damage must be rectified before the issue of any occupation certificate.…

DA-289/2025 det. 26/08/2025

Construction Cranes May Require Separate Approval Separate approval must be sought (where required) under the relevant Regulations for any equipment (i.e. cranes) required to construct the building. Construction cranes may be required to operate at a height above the proposed development and consequently, may require separate approval under the Regulations. It is advisable that approval to operate equipment (i.e. cranes) be obtained before the issue of any construction certificate. 2.105 Condition reason: To ensure adequate approval of crane use. Car Parking Details Before the issue of the relevant construction certificate, a suitably qualified engineer must review the plans which relate to…

DA-1049/2024 det. 15/04/2025

A copy of the construction site management plan must be kept on-site at all times while work is being carried out. 2.401 Condition reason: To provide and maintain orderly and safe areas for vehicular and pedestrian movement / parking. Sight Triangles on Plans Sight triangles are to be marked on relevant plans, being provided at the intersection of the driveway and the property boundary in accordance with AS 2890.1: ‘Figure 3.3 – Minimum Sight Lines for Pedestrian Safety’. A splay extending 2 metres from the driveway edge along the front boundary and 2.5 metres from the boundary along the driveway shall be provided to give clear sight lines of pedestrians from vehicles exiting the site and…

Condition 38 DA-1182/2024 det. 13/02/2026 Compass Centre

38. Driveway Design The design, layout, signage, line marking, lighting and physical controls of all off- street parking facilities must comply with the minimum requirements of Australian Standard AS/NZS 2890.1 Parking facilities Part 1: Off-street car parking, AS/NZS 2890.2 Parking facilities Part 2: Off-street commercial vehicle facilities and AS/NZS 2890.6 Parking facilities Part 6: Off-street parking for people with disabilities. The details must be submitted to and approved by the certifier before a relevant construction certificate being issued. Furthermore, for internal driveways with a gradient exceeding 10% (1 in 10), longitudinal profiles of all vehicular driveways and ramps shall…

DA-811/2025 det. 08/12/2025

Condition reason: To protect and enhance the amenity of the occupants of the development site and the occupants of adjoining sites. • On-Site Waste Collection Before the issue of any construction certificate, the certifier must receive written confirmation from Council, that Council has been provided to its satisfaction with the following: • Detailed plans showing that the waste storage rooms identified on stamped plans will be capable of being accessed from the designed access roadway by a Heavy Rigid Vehicle (HRV) in accordance with AS2890.2, and that a loading area is available for the vehicle when collecting waste that meets the following requirements: • Within 10 metres of the all…

Condition 171 DA-1182/2024 det. 13/02/2026 Compass Centre

171. Hours of operation The hours of operation of the use shall be limited to between: Hotel • Hotel restaurant: 6.30am to 9.30pm Monday to Sunday; • Hotel Restaurant Terrace: 8am to 8.30pm Monday to Sunday; • Hotel Bar: 4pm to 10pm Monday to Sunday; • Hotel rooftop bar: 4pm to 11pm Monday to Sunday; and • Meeting/Incentives/conferences/exhibition rooms: 8am to 12midnight Monday to Sunday. Ground Floor • Ground floor retail: 6am to 10pm Monday to Sunday • All public access areas: shall be closed from 10pm onwards Monday to Sunday Podium (Level 01, Level 02, Level 03, Level 04) • Public access areas (including podium car park): 7am to 10pm Monday to Sunday Medical suites • 7am to 6.30pm…

Condition 131 DA-1182/2024 det. 13/02/2026 Compass Centre

131. Allocation of car parking spaces Four-hundred and ninety-four (494) off-street car parking spaces shall be provided and maintained in accordance with the approved plans. This shall comprise: a. Residential: 239 (including at least 34 accessible spaces) b. Retail and gym: 124 (including 3 accessible spaces) c. Hotel: 78 (including 2 accessible spaces) d. Medical suites: 28 (including 1 accessible space) e. Child care centre: 25 (including 1 accessible space) Note: At least forty-one (41) of the required car parking spaces are to be provided for people with mobility impairment in accordance with AS 2890.1. All car parking spaces shall be allocated and marked according to these…

Condition 51 DA-1182/2024 det. 13/02/2026 Compass Centre

51. Bin Carting Route The certifier must not issue the relevant construction certificate unless provided with detailed plans that form part of the construction certificate which identify that the bin carting route from the communal bin storage room to the waste collection point identified on stamped plans complies with the following requirements as DA-1182/2024 22 well as the requirements of Council’s “Waste Management Guide for New Developments”: a. Is direct and less than 10.0 / 15.0 metres in length, b. Has a minimum width of 2.0 metres of hard surface; c. Is of non-slip material and free from obstacles and steps; d. Is not located within a driveway or carpark; e. Has a maximum grade of…

Condition 40 DA-1182/2024 det. 13/02/2026 Compass Centre

40. Small Car Parking The design and layout of all off-street car parking must comply with the minimum requirements of Australian Standard AS/NZS 2890.1 - Parking facilities Part 1: Off-street car parking and AS2890.2 – Parking Facilities Part 2: Off-street commercial vehicle facilities. Where physical kerb separators between opposing traffic flow, can’t be installed along all internal ramps and circulation roadways connecting different parking levels, appropriate line marking with additional Raised Pavement Markers (RPM) shall be installed. The details must be submitted and approved by the certifier before a relevant construction certificate being issued. Condition reason: To ensure…

Condition 13 DA-1182/2024 det. 13/02/2026 Compass Centre

13. Access Intercom Where a boom gate or barrier control is in place, the residential visitor spaces must be accessible to visitors by the location of an intercom (or card controller system) at the car park entry, installed at least 4 metres recessed into the site, when measured from the property boundary with the street. The intercom is to be wired to all units. This is to be to the satisfaction of the certifier prior to the issue of the relevant construction certificate. The intercom must comply with Australian Standard AS 1428.2: Design for access and mobility - Enhance and additional requirements - Building and facilities Sections 22 and 23. Condition reason: To provide and maintain…

Condition 175 DA-1182/2024 det. 13/02/2026 Compass Centre

175. NSW Police Conditions The following conditions shall be complied with at all times: a. To reduce the risk and opportunity for mail theft, mailboxes are to be placed in a location that maximises passive and CCTV surveillance by residents, tenants and on-site management. b. Access control measures shall be in place to prevent unauthorised access to hotel and residential towers from building entrances and underground car parks; c. The comprehensive Plan of Management address measures and outlines a framework of responsibility of on-site managers and duties. DA-1182/2024 56 Condition reason: To protect and enhance the amenity of the occupants of the development site and the occupants of…

Condition 31 DA-1182/2024 det. 13/02/2026 Compass Centre

31. Pump Out System The pump out drainage system for the basement driveway ramp and car parking area shall be provided in accordance with Council's Development Engineering Standards. The engineer must design the Pump out drainage system to be in accordance with the Australian Standards AS 3500.3. Engineering details and manufacturers specifications for the pumps, switching system and sump pit shall be submitted to the certifier for approval before issue of the relevant construction certificate. The engineer must certify that the hydraulic design complies with the above relevant standards. Condition reason: To ensure compliance with the relevant Australian Standard and National Construction…

Condition 184 DA-1182/2024 det. 13/02/2026 Compass Centre

184. Use of Car Parking Spaces and Driveways The car parking spaces, driveways and manoeuvring areas must be used solely for vehicular access and for the parking of vehicles associated with the use of the premises. The car parking spaces, driveways and manoeuvring areas must not be used for the manufacture, storage or display of goods, materials or any other equipment (includes mobile food vending vehicles). Condition reason: To ensure the development is built and remains consistent with approved plans and documentation and to provide and maintain orderly and safe areas for vehicular and pedestrian movement / parking.

Condition 133 DA-1182/2024 det. 13/02/2026 Compass Centre

133. Bicycle parking spaces The minimum number of bicycle parking spaces is to be provided for the development must comply with the below. DA-1182/2024 46 a. 102 Residential a. 39 Residential visitor b. 43 Non-residential Note: The layout, design and security of bicycle facilities must comply with the minimum requirements of Australian Standard AS 2890.3 – ‘Parking Facilities’ Part 3: Bicycle Parking Facilities and ‘Austroads Bicycle Parking Facilities: Guidelines for Design and Installation.’ Condition reason: To provide and maintain orderly and safe areas for vehicular and pedestrian movement / parking.

Condition 48 DA-1182/2024 det. 13/02/2026 Compass Centre

48. Sight Triangles on Plans Sight triangles are to be marked on the relevant construction certificate plans, being provided at the intersection of the driveway and the property boundary in accordance with AS 2890.1:2004 ‘Figure 3.3 – Minimum Sight Lines for Pedestrian Safety’. The sight triangle shall extend 2 metres from the driveway edge along the property boundary and 2.5 metres from the boundary along the driveway and is to be kept clear of any obstructions. Condition reason: To provide and maintain orderly and safe areas for vehicular and pedestrian movement / parking.

Condition 138 DA-1182/2024 det. 13/02/2026 Compass Centre

138. Mechanical ventilation Before the issue of an occupation certificate, the principal certifier must ensure that the car park is ventilated in accordance with the Building Code of Australia and, where necessary, Australian Standard AS 1668, Parts 1 and 2. Ventilation must be controlled by carbon monoxide monitoring sensors to ensure compliance with occupant health requirements. Condition reason: To protect and enhance the amenity of the occupants of the development site and the occupants of adjoining sites.

Condition 12 DA-1182/2024 det. 13/02/2026 Compass Centre

12. Car Parking Details Before the issue of the relevant construction certificate, a suitably qualified engineer must review the plans which relate to parking facilities and provide written evidence, to the certifier’s satisfaction, that it complies with the relevant parts of AS 2890 – ‘Parking Facilities - Off-Street Carparking’ and Council’s development control plan. Condition reason: To provide and maintain orderly and safe areas for vehicular and pedestrian movement / parking.

Condition 132 DA-1182/2024 det. 13/02/2026 Compass Centre

132. Accessible car allocations For residential development, accessible car parking spaces for people with mobility impairment are only to be allocated as visitor parking or to adaptable units. Where allocated to adaptable units, the unit(s) and car spaces must be assigned to the unit in any future strata subdivision of the building. Condition reason: To ensure orderly development of land.

Condition 4 DA-1524/2023

4. Add additional Condition 139A under “Before Issue of an Occupation Certificate” Section to read as follows: Electrical Vehicle charging equipment The measures listed under condition 63A shall be implemented on site prior to the issue of an Occupation Certificate Condition reason: To ensure compliance with the relevant policy.

Condition 60 DA-1182/2024 det. 13/02/2026 Compass Centre

60. Carpark Exhaust Before the issue of a relevant construction certificate, the certifier is to ensure that all carpark exhaust does not directly vent into private or communal open space. Condition reason: To ensure compliance with the relevant Australian Standard and National Construction Code.

Snippets shown for reference only. Verify against the original consent on the NSW Planning Portal.