21 traffic & access conditions imposed by Camden across 8 development applications in our dataset. Traffic and access conditions address vehicle and pedestrian movement — driveway and vehicle crossing design, sight lines, road and footpath works, traffic management plans and access for service and emergency vehicles.

Condition 2 DA/2025/414/1 det. 11/12/2025 Seven storey RFB

2. The provision of fixed-line telecommunications infrastructure in the fibre-ready facilities to all individual lots and/or premises in a real estate development project demonstrated through an agreement with a carrier. Condition reason: To ensure fibre-ready telecommunications facilities are installed for new development. (4) Glass reflectivity index - Before the issue of a construction certificate, information must be prepared by a suitably qualified person and demonstrate, to the certifier's satisfaction, that the glass reflectivity index for all glass used externally will not exceed 20%. Condition reason: To ensure all glass used externally has a reasonable maximum level of…

Condition 2 DA/2025/284/1 det. 07/11/2025 Construction of a six (6) storey hotel development

2. The provision of fixed-line telecommunications infrastructure in the fibre-ready facilities to all individual lots and/or premises in a real estate development project demonstrated through an agreement with a carrier. Condition reason: To ensure fibre-ready telecommunications facilities are installed for new development. (6) Glass reflectivity index - Before the issue of a construction certificate, information must be prepared by a suitably qualified person and demonstrate, to the certifier's satisfaction, that the glass reflectivity index for all glass used externally will not exceed 20%. Condition reason: To ensure all glass used externally has a reasonable maximum level of…

Condition 2 DA/2025/203/1 det. 09/09/2025 Stage 5 - Leppington Anglican College

2. The provision of fixed-line telecommunications infrastructure in the fibre-ready facilities to the project demonstrated through an agreement with a carrier. Condition reason: To ensure fibre-ready telecommunications facilities are installed for new development. (4) Glass reflectivity index - Before the issue of a construction certificate, information must be prepared by a suitably qualified person and demonstrate, to the certifier's satisfaction, that the glass reflectivity index for all glass used externally will not exceed 20%. Condition reason: To ensure all glass used externally has a reasonable maximum level of reflectivity. (5) Outdoor lighting provision - Before the issue of a…

Condition 4 DA/2025/432/1 det. 11/12/2025 Construction of a six-storey high-grade commercial building

4. The assessment under point 3 of this condition must specify the following: a. The rated annual electricity use. b. If the development will not achieve the energy use standards - the difference between the rated annual electricity use and the energy use standards, calculated for the first 5 years of operation. c. The rated use of on-site fossil fuels and the associated amount of carbon dioxide measured as carbon dioxide equivalent or CO e, calculated for the 2 first 10 years of operation. Condition reason: Prescribed condition under section 79A of the Environmental Planning and Assessment Regulation 2021. (5) Engineering specifications - The development must be designed and constructed in…

Condition 3 DA/2025/284/1 det. 07/11/2025 Construction of a six (6) storey hotel development

3. The LA10, 15min noise level emitted from the licensed premises when measured inside a habitable room of a residence between 12pm and 7am must not give rise to a measurable increase above the ambient level in any octave band centre frequency (31.5Hz-8kHz inclusive) in the absence of music. *In this condition, LA10 is taken as the average maximum deflection of the noise emission from the licensed premises. Condition reason: To ensure that hazardous materials are safely stored and used. (19) On-site detention facility plan of management (ongoing) - During occupation and ongoing use of the development, the on-site detention facility plan of management plan required by this development must…

Condition 5 DA/2025/309/1 det. 25/09/2025 Child Care Centre

5. Roofed with a minimum ceiling height of 2.4m. Condition reason: To ensure that hygienic waste management facilities are provided. (12) Bottle preparation room finishes - Wall finishes are required to be compliant with AS 4674-2004 to the entire wall from floor to ceiling. Where cupboards are installed, the wall finishes are required to be applied from the bench to the ceiling. All cupboards are required to either be on solid plinths, on legs with 150mm clearance off the floor or on castor wheels. Condition reason: To ensure bottle preparation rooms comply with the Australian Standards. (13) Mechanical Ventilation Commercial Dishwasher - Mechanical ventilation provision shall be…

Condition 2 DA/2025/309/1 det. 25/09/2025 Child Care Centre

2. The provision of fixed-line telecommunications infrastructure in the fibre-ready facilities to all individual lots and/or premises in a real estate development project demonstrated through an agreement with a carrier. Condition reason: To ensure fibre-ready telecommunications facilities are installed for new development. (4) Glass reflectivity index - Before the issue of a construction certificate, information must be prepared by a suitably qualified person and demonstrate, to the certifier's satisfaction, that the glass reflectivity index for all glass used externally will not exceed 20%. Condition reason: To ensure all glass used externally has a reasonable maximum level of…

Condition 4 DA/2025/390/1 det. 11/12/2025 Macarthur Anglican School

4. Relevant line marking and signage shall be annotated at the new northern access road and associated car park. Design shall be in accordance with AS2890.1-2004. Condition reason: To ensure that required information is provided to the certifier. (10) Engineering specifications - Before the issue of a construction certificate, civil engineering plans and information must be prepared by a suitably qualified civil OFFICIAL engineer and demonstrate, to the certifier’s satisfaction, that the development has been designed to comply with Council’s engineering specifications, the approved plans and documents and the conditions of this development consent. Condition reason: To ensure that the…

Condition 2 da/2025/17/1 det. 27/06/2025 Childcare Centre

2. The provision of fixed-line telecommunications infrastructure in the fibre-ready facilities to all individual lots and/or premises in a real estate development project demonstrated through an agreement with a carrier. Condition reason: To ensure fibre-ready telecommunications facilities are installed for new development. (5) Glass reflectivity index - Before the issue of a construction certificate, information must be prepared by a suitably qualified person and demonstrate, to the certifier's satisfaction, that the glass reflectivity index for all glass used externally will not exceed 20%. Condition reason: To ensure all glass used externally has a reasonable maximum level of…

Condition 2 DA/2025/167/1 det. 09/09/2025 Animal Boarding and Training Establishment and Plant Nursery

2. The provision of fixed-line telecommunications infrastructure in the fibre-ready facilities to the project demonstrated through an agreement with a carrier. Condition reason: To ensure fibre-ready telecommunications facilities are installed for new development. (3) Smoke alarms - Before the issue of a construction certificate, information must be prepared by a suitably qualified person and demonstrate, to the certifier’s satisfaction, that the development will provide smoke alarms that comply with AS 3786 - Smoke Alarms Using Scattered Light, Transmitted Light or Ionization. Condition reason: To ensure the provision of smoke alarms that comply with industry standards. (4) Driveway design…

Condition 3 da/2025/17/1 det. 27/06/2025 Childcare Centre

3. The approved basement car park plans are to be amended to ensure 1m end of aisle clearance is achieved as required by the relevant Australian standard. Condition reason: To require minor amendments to the plans endorsed by the consent authority following assessment of the development. (13) Engineering specifications - Before the issue of a construction certificate, civil engineering plans and information must be prepared by a suitably qualified civil engineer and demonstrate, to the certifier’s satisfaction, that the development has been designed to comply with Council’s engineering specifications, the approved plans and documents and the conditions of this development consent. Condition…

Condition 1 DA/2025/414/1 det. 11/12/2025 Seven storey RFB

1. Endeavour Energy, CNR-86032, dated 28 August 2025. Condition reason: To ensure the development complies with Authority requirements. (3) Fulfillment of BASIX commitments - Each commitment listed in an approved BASIX certificate for the following development must be fulfilled as per the approved BASIX Certificate. Condition reason: Prescribed condition under section 75 of the Environmental Planning and Assessment Regulation 2021. (4) Engineering specifications - The development must be designed and constructed in accordance with Council’s engineering specifications. Condition reason: To ensure the development complies with Council’s engineering specifications. (5) Approved tree work -…

Condition 3 DA/2025/432/1 det. 11/12/2025 Construction of a six-storey high-grade commercial building

3. AS 3666 - Air Handling and Water Systems of Buildings. Condition reason: To ensure that regulated systems are installed in accordance with statutory requirements and industry standards. (7) Water management facilities positive covenant - Before the issue of an occupation certificate, evidence must be provided and demonstrate, to the principal certifier’s satisfaction, that a positive covenant has been registered with NSW Land Registry Services. The positive covenant must be created under Section 88E of the Conveyancing Act 1919 and burden the property owner with a requirement to maintain any on-site detention, on-site retention/re-use and water quality facilities on the property. The…

Condition 3 DA/2025/390/1 det. 11/12/2025 Macarthur Anglican School

3. Inspection and maintenance requirements (including time intervals for inspections and maintenance). Condition reason: To provide a management regime for on-site detention facilities. (5) Water management facilities positive covenant - Before the issue of an occupation certificate, evidence must be provided and demonstrate, to the principal certifier’s satisfaction, that a positive covenant has been registered with NSW Land Registry Services. The positive covenant must be created under Section 88E of the Conveyancing Act 1919 and burden the property owner with a requirement to maintain any on-site detention, on-site retention/re-use and water quality facilities on the property. The terms…

Condition 5 DA/2025/432/1 det. 11/12/2025 Construction of a six-storey high-grade commercial building

5. For roads and car parks: a. Pavement design. b. Traffic management devices. c. Line marking. The plans and information must be accompanied by certification from a suitably qualified civil engineer certifying that they comply with Council’s engineering specifications. Condition reason: To ensure that civil works are designed to appropriate standards. (12) Detailed landscaping plan - Before the issue of a construction certificate, detailed landscaping plans must be prepared by a registered landscape architect and demonstrate, to the certifier’s satisfaction, the following detailed design requirements:

Condition 5 da/2025/17/1 det. 27/06/2025 Childcare Centre

5. For roads and car parks: a. Pavement design. b. Traffic management devices. c. Line marking. The plans and information must be accompanied by certification from a suitably qualified civil engineer certifying that they comply with Council’s engineering specifications. Condition reason: To ensure that civil works are designed to appropriate standards. (18) Detailed landscaping plan - Before the issue of a construction certificate, detailed landscaping plans must be prepared by a registered landscape architect and demonstrate, to the certifier’s satisfaction, the following detailed design requirements:

Condition 5 DA/2025/167/1 det. 09/09/2025 Animal Boarding and Training Establishment and Plant Nursery

5. Construction traffic management in accordance with Council’s engineering specifications and AS 1742.3 - Manual of Uniform Traffic Control Devices - Traffic Control for Works on Roads.

Condition 5 DA/2025/390/1 det. 11/12/2025 Macarthur Anglican School

5. Construction traffic management in accordance with Council’s engineering specifications and AS 1742.3 - Manual of Uniform Traffic Control Devices - Traffic Control for Works on Roads.

Condition 4 DA/2025/284/1 det. 07/11/2025 Construction of a six (6) storey hotel development

4. AS 1657 - Fixed Platforms, Walkways, Stairways and Ladders - Design, Construction and Installation.

Condition 5 DA/2025/203/1 det. 09/09/2025 Stage 5 - Leppington Anglican College

5. For roads and car parks: a. Pavement design. b. Traffic management devices. c. Line marking.

Condition 5 DA/2025/284/1 det. 07/11/2025 Construction of a six (6) storey hotel development

5. For roads and car parks: a. Pavement design. b. Traffic management devices. c. Line marking.